Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | Sparsh 400 |
Usage/Application | OT |
Maximum Power | 400W |
Brand | Easemed |
Bipolar Coag | 150W |
Blend Cut | 250W |
Product Features Salient Features Technical Specification CUT MODE PURE - A high-frequency alternating current yields smooth, rapid cuts that evoke little to no hemostasis. BLEND 1 - Preset blended cut modes give the surgeon varying degrees of hemostasis in cut mode. BLEND 2 - The mode is used for the vaporization of prostatic tissue or any fat tissue. The higher output wattage gives fast cutting eect of the tissue. ENDOCUT - The mode is used to automatically control cut system to reduce the complication rate of endoscopic sphincterotomy (EST) and serum hyperamylasemia after EST compared to the conventional blended cut mode. COAG MODE SPRAY - Spray output is made for direct coagulation at the tissue with spark. This spark does not give any cutting eect as its crest factor is high. FORCE - This mode is a greater degree of homeostasis and covers all demands of standard coagulation. This produce the fine tune waveform that creates superficial resistance in the tissue resulting in superior coagulation where the tissue destroyed by hyper evaporation. FULGURATE - Sparking the tissue to lead to coagulation. There is no tissue-electrode contact; rather, voltage is raised in order to incite a spark between electrodes in order to coagulate the tissue in between. DESICCATE - Coagulation in which the active electrode is in direct contact with the tissue is referred to as desiccation and is the type of coagulation used in most surgeries It ensures pinpoint desiccation with less destruction of peripheral tissue. BIPOLAR MODE MICRO - High Voltage force coagulation for special purpose when speed is required. MACRO - For highly precise control over coagulation process and privations of carbonization. CUT - This Bipolar CUT technology nearly eliminate excessive current, even during precision cutting in minute tissue structure. AUTO - Coagulation start by pressing the footswitch and stops output and audio signal automatically when the tissue is coagulated. • 99 User settable program mode • Frequency: 480khz • Display: 7 in LCD Touchscreen display • Net Weight (Inc Accessories): 8.5 Kg • Dimension: 410 mm (L) x 355 mm (W) x 155 mm (H) • Input Supply Voltage 110V / 230 VAC (+/-15%) 50Hz • Separates Monopolar & Bipolar foot switches CUT MODE MAX POWER LOAD CREAST FACTOR PURE CUT 400 W 300Ω 1.5 BLEND 1 250 W 300Ω 1.5 BLEND 2 200 W 300Ω 1.5 ENDOCUT 99 % 300Ω 1.5 COAG MODE MAX POWER LOAD CREAST FACTOR SPRAY 120 W 300Ω 7 FORCE 120 W 300Ω 6.5 FULGURATE 150 W 300Ω 6 DESICCATE 150 W 300Ω 6 BIPOLAR MODE MAX POWER LOAD CREAST FACTOR MICRO 80 W 100Ω 1.5 MACRO 80 W 100Ω 1.5 CUT 100W 100Ω 1.5 AUTO 100W 100Ω 1.5